Energenie EG-UC-AC1 User Manual

Browse online or download User Manual for Battery chargers Energenie EG-UC-AC1. LVD test report for EG-UC-AC1, EG-UC-AC1-B, EG-UC

  • Download
  • Add to my manuals
  • Print
  • Page
    / 59
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CE
LVD TEST REPORT
Report No. WST13080142-1SR
Product Power adapter
Trade mark: energenie
Model No.
EG-UC-AC1,EG-UC-AC1-B,EG-UC-AC2,EG-UC-AC2-B,
EG-UC-AC3,EG-UC-AC4
Applicant
Shenzhen Gembird Electronics Ltd.
Address
5th floor, Building B, Shifeng Industry Park, Huaning Road,
Dalang Street, Longhua District, Shenzhen
Issued by WST Certification & Testing (HK) Limited
Lab Location
12/F., San Toi Building, 137-139 Connaught Road Central, Hong
Kong
Tel
HongKong Tel: (00852) -21393077 Fax: (00852) -21393217
Shenzhen office: Tel:0755-27822785 Fax:0755-27822175
E-mail:[email protected] Http:// www.wstlab.com
Page view 0
1 2 3 4 5 6 ... 58 59

Summary of Contents

Page 1 - LVD TEST REPORT

CE LVD TEST REPORT Report No.: WST13080142-1SR Product: Power adapter Trade mark: energenie Model No.: EG-UC-AC1,EG-UC-AC1-B,EG-UC-AC2,EG-

Page 2

- Page 10 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 3

- Page 11 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 4

- Page 12 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 5

- Page 13 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 6

- Page 14 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 7

- Page 15 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 8

- Page 16 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 9

- Page 17 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 10 - EN 60950-1

- Page 18 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 11

- Page 19 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 13

- Page 20 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 14

- Page 21 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 15

- Page 22 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 16

- Page 23 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 17

- Page 24 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 18

- Page 25 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 19

- Page 26 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 20

- Page 27 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 21

- Page 28 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 22

- Page 29 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 23

- Page 3 of 59 - Report No.: WST13080142-1SR Summary of testing: Tests performed (name of test and test clause):EN 60950-1: 2006+A11:2009+A1:2010

Page 24

- Page 30 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK)

Page 25

- Page 31 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 26

- Page 32 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 27

- Page 33 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 28

- Page 34 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 29

- Page 35 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 30

- Page 36 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 31 - (A1:2010)

- Page 37 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 32

- Page 38 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 33 -

- Page 39 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 34

- Page 4 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Page 35

- Page 40 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 36 - – 27 mV and 100 dBA – 150 mV

- Page 41 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 37

- Page 42 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 38

- Page 43 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 39

- Page 44 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 40 - EQUIPMENT TYPE A

- Page 45 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 41

- Page 46 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 42

- Page 47 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 43

- Page 48 of 59 - Report No. WST13080142-1SR EU_GD_IEC 60950_1B_II Clause Requirement + Test Result - Remark Verdict WST Certification &

Page 44

- Page 49 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 1.5.1 TABLE: List of critical components

Page 45

- Page 5 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Page 46

- Page 50 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 1.5.1 TABLE: List of critical components

Page 47

- Page 51 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. Condition V0 (V pk) 37% V0 (V pk) 37%(t)

Page 48

- Page 52 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 2.6.3.4 Table: ground continue test N Lo

Page 49

- Page 53 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 4.3.8 TABLE: Batteries N The tests of 4.3.

Page 50

- Page 54 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 4.5 TABLE: Thermal requirements P Supp

Page 51

- Page 55 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 4.5.5 TABLE: Ball pressure test of thermo

Page 52

- Page 56 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. 5.2 TABLE: Electric strength tests, impul

Page 53

- Page 57 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. Output S-C 264V/50Hz 30 min. F1 0 Unit sh

Page 54

- Page 58 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. Photos Fig. 1 Fig. 2

Page 55

- Page 59 of 59 - Report No. WST13080142-1SR WST Certification & Testing (HK) Limited. Fig. 3 Fig. 4 ===== End of Test Repor

Page 56

- Page 6 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Page 57

- Page 7 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Page 58

- Page 8 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Page 59

- Page 9 of 59 - Report No. WST13080142-1SR EN 60950-1 Clause Requirement + Test Result - Remark Verdict WST Certification & Testing (HK) L

Comments to this Manuals